BT Redcare Secure Issue 16 June 2010
Installation Manual Page 4 of 40 All rights reserved
PRODUCT
SECURE 3
Both paths working, PSTN/IP path fails fault reported in
2 MINS
Both paths working, Radio path fails fault reported in
5-55 MINS
Only Radio path working and it fails fault reported in
55 MINS
Only PSTN/IP path working and it fails fault reported in
5 HOURS
If both paths failed simultaneously fault reported in
55 MINS
Primary Polling Frequency
5 MINS
EN GRADE
3
ATS VALUE PRIMARY
ATS4
ATS VALUE SECONDARY
ATS4
Figure 2 - Polling rates and communication fail alarm transmission times
Note: The polling rates and communication fail alarm transmission times in Fig 2 may be liable to
change. For the latest information, refer to the Technical information sheet at
http://www.redcare.bt.com/partner/brochure_list.htm
Note: Where the Redcare Secure unit is connected to a PSTN line (Secure 2 & 3) then the line
should be either a dedicated line, or a line of low usage, to ensure that the necessary out going
test calls and alarm calls can be made when required.